The [[NeoScan]] system is capable of measuring signals with bandwidths up to 20 GHz and signal levels as low as 1 V/m for optical probes with a 10 m PM fiber. Because the optical probes are free of metallic parts, it is possible to measure extremely high-field strengths since there are no free electron surfaces to generate arcing. The [[NeoScan]] can measure fields up at least 2 MV/m and possibly higher.
1.4 == System Overview ==
The [[NeoScan]] real-time field measurement and scanning system consists of:
=== The Front Panel of [[NeoScan]] Optical Mainframe ===
The front panel is the main interface to the system. It contains a control computer that that runs Microsoft Windows, and controls, commands, and monitors the [[NeoScan]] systemâs status (Figure 1.7).
=== The Rear Panel of [[NeoScan]] Optical Mainframe ===
The rear panel is the interface to the instruments and provides complete access for external control, optical fiber excitation, and RF signal output (Figure 1.8). It contains:
An electric fan
â
â Â 1.5 == Acronyms and Abbreviations ==
V: Volt
    == Shipping & Handling Precautions==
The [[NeoScan]] system contains extremely sensitive and fragile components. Use extreme caution whenever operating this system. Do not attempt to service or adjust or install substitute parts to its components. Please contact EMAG Technologies Inc. for service and more information.
Do not over-tighten the optical connectors.
2.2 === Installing the [[NeoScan]] System===
[[NeoScan]] optical mainframe is enclosed in a 4U case with dimensions of 24â(H) x 17â(L) x 13â (W) (61cm x 43cm x 33cm). The instrument weighs 60 pounds (27kg) and contains the entire optical system, control systems, and power conditioning circuits required for electric field measurements. It is packaged in foam. Open the cardboard box and remove the layers of foam. Care must be taken to ensure the optical connectors, the SMA connectors, and the USB connectors on the rear panel are not damaged. Remove the fiber port protection caps and keep safe for reuse when repacking the instrument. The instrument box should contain the corresponding power cord, cables and etc.
Attach the Plastic Probe Fixture to the XYZ Miniature Translation Stage.
2.4 === Unpacking the EO Probes===
The [[NeoScan]] probes are extremely sensitive and fragile components. Use extreme caution whenever operating them. EO probes have been packed in separate boxes (Figure 2.3). The probes are delicate, care must be taken to ensure that the fiber and probe tip are not bent hard or dropped. The probe heads are placed in foam and the probes are housed in a box surrounded by bubble wrap on all sides.