EM.Picasso

From Emagtech Wiki
Jump to: navigation, search
Splash-planar new.jpg

Fast Full-Wave Simulator For Modeling Multilayer Planar Structures

Cube-icon.png Cad-ico.png Fdtd-ico.png Prop-ico.png Static-ico.png Metal-ico.png Po-ico.png

Tutorial icon.png EM.Picasso Tutorial Gateway

Back icon.png Back to EM.Cube Main Page

Product Overview

EM.Picasso in a Nutshell

EM.Picasso® is a versatile planar structure simulator for modeling and design of printed antennas, planar microwave circuits, and layered periodic structures. EM.Picasso's simulation engine is based on a 2.5-D full-wave Method of Moments (MoM) formulation that provides the ultimate modeling accuracy and computational speed for open-boundary multilayer structures. It can handle planar structures with arbitrary numbers of metal layouts, slot traces, vertical interconnects and lumped elements interspersed among different substrate layers.

Since its introduction in 2002, EM.Picasso has been successfully used by numerous users around the globe in industry, academia and government. It has also undergone several evolutionary cycles including a total reconstruction based on our integrated EM.Cube software foundation to expand its CAD and geometrical construction capabilities. EM.Picasso's integration with EM.Cube facilitates import and export of many popular CAD formats (including DXF export of layered traces) and provides a seamless interface with EM.Cube's other simulation tools.

Info icon.png Click here to learn more about the Theory of Planar Method of Moments.

3D radiation pattern of a slot-coupled patch antenna array with a corporate feed network.

EM.Picasso as the Planar Module of EM.Cube

EM.Picasso is the frequency-domain, full-wave Planar Module of EM.Cube, a comprehensive, integrated, modular electromagnetic modeling environment. EM.Picasso shares the visual interface, 3D parametric CAD modeler, data visualization tools, and many more utilities and features collectively known as CubeCAD with all of EM.Cube's other computational modules.

Info icon.png Click here to learn more about EM.Cube Modeling Environment.

Advantages & Limitations of EM.Picasso's Planar MoM Simulator

EM.Picasso assumes that your planar structure has a substrate (background structure) of infinite lateral extents. In addition, the planar 2.5-D assumption restricts the 3D objects of your physical structure to embedded prismatic objects that can only support vertical currents. These assumptions limit the variety and scope of the applications of EM.Picasso. For example, you cannot use EM.Picasso to analyze a patch antenna with a finite-sized dielectric substrate. If the substrate edge effects are of concern in your modeling problem, you must use EM.Tempo instead. On the other hand, since EM.Picasso's Planar MoM simulation engine incorporates the Green's functions of the background structure into the analysis, only the finite-sized traces like microstrips and slots are discretized by the mesh generator. As a result, the size of EM.Picasso's computational problem is normally much smaller than that of EM.Tempo. In addition, EM.Picasso generates a hybrid rectangular-triangular mesh of your planar structure with a large number of equal-sized rectangular cells. Taking full advantage of all the symmetry and invariance properties of dyadic Green's functions often results in very fast computation times that easily make up for EM.Picasso's limited applications. A particularly efficient application of EM.Picasso is the modeling of periodic multilayer structures at oblique incidence angles.

The hybrid planar mesh of the slot-coupled patch antenna array.

EM.Picasso Features at a Glance

Structure Definition

  • Multilayer stack-up with unlimited number of substrate layers and trace planes
  • PEC and conductive sheet traces for modeling ideal and non-ideal metallic layouts
  • PMC traces for modeling slot layouts
  • Vertical metal interconnects and embedded dielectric objects
  • Full periodic structure capability with inter-connected unit cells
  • Periodicity offset parameters to model triangular, hexagonal or other offset periodic lattice topologies

Sources, Loads & Ports

  • Gap sources on lines
  • De-embedded sources on lines for S parameter calculations
  • Probe (coaxial feed) sources on vias
  • Gap arrays with amplitude distribution and phase progression
  • Periodic gaps with beam scanning
  • Multi-port and coupled port definitions
  • RLC lumped elements on strips with series-parallel combinations
  • Short dipole sources
  • Import previously generated wire mesh solution as collection of short dipoles
  • Plane wave excitation with linear and circular polarizations
  • Multi-ray excitation capability (ray data imported from EM.Terrano or external files)
  • Huygens sources imported from other EM.Cube modules

Mesh Generation

  • Optimized hybrid mesh with rectangular and triangular cells
  • Regular triangular surface mesh
  • Local meshing of trace groups
  • Local mesh editing of planar polymesh objects
  • Fast mesh generation of array objects

Planar MoM Simulation

  • 2.5-D mixed potential integral equation (MPIE) formulation of planar layered structures
  • 2.5-D spectral domain integral equation formulation of periodic layered structures
  • Accurate scattering parameter extraction and de-embedding using Prony's method
  • Plane wave excitation with arbitrary angles of incidence
  • A variety of matrix solvers including LU, BiCG and GMRES
  • Uniform and fast adaptive frequency sweep
  • Parametric sweep with variable object properties or source parameters
  • Generation of reflection and transmission coefficient macromodels
  • Multi-variable and multi-goal optimization of structure
  • Remote simulation capability
  • Both Windows and Linux versions of Planar MoM simulation engine available

Data Generation & Visualization

  • Current distribution intensity plots
  • Near field intensity plots (vectorial - amplitude & phase)
  • Far field radiation patterns: 3D pattern visualization and 2D Cartesian and polar graphs
  • Far field characteristics such as directivity, beam width, axial ratio, side lobe levels and null parameters, etc.
  • Radiation pattern of an arbitrary array configuration of the planar structure or periodic unit cell
  • Reflection and Transmission Coefficients of Periodic Structures
  • Monostatic and bi-static RCS 
  • Port characteristics: S/Y/Z parameters, VSWR and Smith chart
  • Touchstone-style S parameter text files for direct export to RF.Spice or its Device Editor
  • Huygens surface generation
  • Custom output parameters defined as mathematical expressions of standard outputs

Building a Planar Structure in EM.Picasso

EM.Picasso is intended for construction and modeling of planar layered structures. By a planar structure we mean one that contains a background substrate of laterally infinite extents, made up of one or more material layers all stacked up vertically along the Z-axis. Planar objects of finite size are interspersed among these substrate layers. The background structure in EM.Picasso is called the "Layer Stack-up". The layer stack-up is always terminated from the top and bottom by two infinite half-spaces. The terminating half-spaces might be the free space, or a perfect conductor (PEC ground), or any material medium. Most planar structures used in RF and microwave applications such as microstrip-based components have a PEC ground at their bottom. Some structures like stripline components are sandwiched between two grounds (PEC half-spaces) from both their top and bottom.

EM.Picasso's navigation tree and trace types.

Defining the Layer Stack-Up

When you start a new project in EM.Picasso, there is always a default background structure that consists of a finite vacuum layer with a thickness of one project unit sandwiched between a vacuum top half-space and a PEC bottom half-space. Every time you open EM.Picasso or switched to it from EM.Cube's other modules, the Stack-up Settings Dialog opens up. This is where you define the entire background structure. Once you close this dialog, you can open it again by right-clicking the Layer Stack-up item in the Computational Domain section of the navigation tree and selecting Layer Stack-up Settings... from the contextual menu. Or alternatively, you can select the menu item Simulate > Computational Domain > Layer Stack-up Settings...

The Stack-up Settings dialog has two tabs: Layer Hierarchy and Embedded Sets. The Layer Hierarchy tab has a table that shows all the background layers in hierarchical order from the top half-space to the bottom half-space. It also lists the material composition of each layer, Z-coordinate of the bottom of each layer, its thickness (in project units) and material properties: permittivity (εr), permeability (μr), electric conductivity (σ) and magnetic conductivity (σm). There is also a column that lists the names of embedded object sets inside each substrate layer, if any.

EM.Picasso's Layer Stack-up Settings dialog with the initial default values.

You can add new layers to your project's stack-up or delete its layers, or move layers up or down and thus change the layer hierarchy. To add a new background layer, click the arrow symbol on the Insert… button at the bottom of the dialog and select Substrate Layer from the button's dropdown list. A new dialog opens up where you can enter a label for the new layer and values for its material properties and thickness in project units. You can delete a layer by selecting its row in the table and clicking the Delete button. To move a layer up and down, click on its row to select and highlight it. Then click either the Move Up or Move Down buttons consecutively to move the selected layer to the desired location in the stack-up. Note that you cannot delete or move the top or bottom half-spaces. After creating a substrate layer, you can always edit its properties in the Layer Stack-up Settings dialog. Click on any layer's row in the table to select and highlight it and then click the Edit button. The substrate layer dialog opens up, where you can change the layer's label and assigned color as well as its constitutive parameters.

Info icon.png Click here for a general discussion of Materials in EM.Cube.

Info icon.png Click here to learn more about Using EM.Cube's Materials Database.

For better visualization of your planar structure, EM.Picasso displays a virtual domain in a default orange color to represent part of the infinite background structure. The size of this virtual domain is a quarter wavelength offset from the largest bounding box that encompasses all the finite objects in the project workspace. You can change the size of the virtual domain or its display color from the Domain Settings dialog, which you can access either by clicking the Computational Domain Domain icon.png button of the Simulate Toolbar, or using the keyboard shortcut Ctrl+A. Keep in mind that the virtual domain is only for visualization purposes and its size does not affect the MoM simulation. The virtual domain also shows the substrate layers in translucent colors. If you assign different colors to your substrate layers, you have get a better visualization of multilayer virtual domain box surrounding your project structure.

EM.Picasso's Layer Stack-up Settings dialog showing a multilayer substrate configuration.
EM.Picasso's Add Substrate Layer dialog.
A microstrip-fed, slot-coupled patch antenna on a double-layer substrate with a PEC ground plane in the middle hosting the coupling slot.

Planar Object & Trace Types

EM.Picasso groups objects by their trace type and their hierarchical location in the substrate layer stack-up. A trace is a group of finite-sized planar objects that have the same material properties, same color and same Z-coordinate. All the planar objects belonging to the same metal or slot trace group are located on the same horizontal boundary plane in the layer stack-up. All the embedded objects belonging to the same embedded set lie inside the same substrate layer and have same material composition.

EM.Picasso provides the following types of objects for building a planar layered structure:

Icon Material Type Applications Geometric Object Types Allowed
Pec group icon.png Perfect Electric Conductor (PEC) Trace Modeling perfect metal traces on the interface between two substrate layers Only surface objects
Voxel group icon.png Conductive Sheet Trace Modeling lossy metal traces with finite conductivity and finite metallization thickness Only surface objects
Pmc group icon.png Slot Trace Modeling cut-out slot traces and apertures on an infinite PEC ground plane Only surface objects
Pec group icon.png Embedded PEC Via Set Modeling small and short vertical vias and plated-through holes inside substrate layers Only surface objects
Diel group icon.png Embedded Dielectric Object Set Modeling small and short dielectric material inserts inside substrate layers Only surface objects
Virt group icon.png Virtual Object Used for representing non-physical items All types of objects

Click on each category to learn more details about it in the Glossary of EM.Cube's Materials, Sources, Devices & Other Physical Object Types.

You can define two types of metallic traces in EM.Picasso: PEC Traces and Conductive Sheet Traces. PEC traces represent infinitesimally thin (zero thickness) planar metal objects that are deposited or metallized on or between substrate layers. PEC objects are modeled by surface electric currents. Conductive sheet traces, on the other hand, represent imperfect metals. They have a finite conductivity and a very small thickness expressed in project units. A surface impedance boundary condition is enforced on the surface of conductive sheet objects.

Slot Traces are used to model cut-out slots and apertures in PEC ground planes. Planar slot objects are always assumed to lie on an infinite horizontal PEC ground plane with zero thickness, which is not explicitly displayed in the project workspace and its presence is implied. They are modeled by surface magnetic currents. When a slot is excited, tangential electric fields are formed on the aperture, which can be modeled as finite magnetic surface currents confined to the area of the slot. In other words, instead of modeling the electric surface currents on an infinite PEC ground around the slot, one can alternatively model the finite-extent magnetic surface currents on a perfect magnetic conductor (PMC) trace. Slot (PMC) objects provide the electromagnetic coupling between the two sides of an infinite PEC ground plane.

Besides planar metal and slot traces, EM.Picasso allows you to insert prismatic embedded objects inside the substrate layers. The height of such embedded objects is always the same as the height of their host substrate layer. Two types of embedded object sets are available: PEC Via Sets and Embedded Dielectric Sets. PEC via sets are metallic objects such as shorting pins, interconnect vias, plated-through holes, etc. all located and grouped together inside the same substrate layer. The embedded via objects are modeled as vertical volume conduction currents. Embedded dielectric sets are prismatic dielectric objects inserted inside a substrate layer. You can define a finite permittivity and conductivity for such objects. The embedded dielectric objects are modeled as vertical volume polarization currents.

Attention icon.png The height of an embedded object is always identical to the thickness of its host substrate layer.

Defining Traces & Embedded Object Sets

When you start a new project in EM.Picasso, the project workspace looks empty, and there are no finite objects in it. However, a default background structure is always present. Finite objects are defined as part of traces or embedded sets. Once defined, you can see a list of project objects in the Physical Structure section of the navigation tree. Traces and object sets can be defined either from Layer Stack-up Settings dialog or from the navigation tree. In the Layer Stack-up Settings dialog, you can add a new trace to the stack-up by clicking the arrow symbol on the Insert button of the dialog. You have to choose from Metal (PEC), Slot (PMC) or Conductive Sheet options. A respective dialog opens up, where you can enter a label and assign a color. Once a new trace is defined, it is added, by default, to the top of the stack-up table underneath the top half-space. From here, you can move the trace down to the desired location on the layer hierarchy. Every time you define a new trace, it is also added under the respective category in the navigation tree. Alternatively, you can define a new trace from the navigation tree by right-clicking on one of the trace type names and selecting Insert New PEC Trace...or Insert New PMC Trace...or Insert New Conductive Sheet Trace... A respective dialog opens up for setting the trace properties. Once you close this dialog, it takes you directly to the Layer Stack-up Settings dialog so that you can set the right position of the trace on the stack-up.

Embedded object sets represent short material insertions inside substrate layers. They can be metal or dielectric. Metallic embedded objects can be used to model vias, plated-through holes, shorting pins and interconnects. These are called PEC via sets. Embedded dielectric objects can be used to model air voids, thin films and material inserts in metamaterial structures. Embedded objects can be defined either from the Layer Stack-up Settings dialog or directly from the navigation tree. Open the "Embedded Sets" tab of the stack-up dialog. This tab has a table that lists all the embedded object sets along with their material type, the host substrate layer, the host material and their height. To add a new object set, click the arrow symbol on the Insert button of the dialog and select one of the two options, PEC Via Set or Embedded Dielectric Set, from the dropdown list. This opens up a new dialog where first you have to set the host layer of the new object set. A dropdown list labeled "Host Layer" gives a list of all the available finite substrate layers. You can also set the properties of the embedded object set, including its label, color and material properties. Keep in mind that you cannot control the height of embedded objects. Moreover, you cannot assign material properties to PEC via sets, while you can set values for the Permittivityr) and Electric Conductivity(σ) of embedded dielectric sets. Vacuum is the default material choice. To define an embedded set from the navigation tree, right-click on the Embedded Object Sets item in the Physical Structure section of the navigation tree and select either Insert New PEC Via Set... or Insert New Embedded Dielectric Set... The respective New Embedded Object Set dialog opens up, where you can set the properties of the new object set. As soon as you close this dialog, it takes you to the Layer Stack-up Settings dialog, where you can verify the location of the new object set on the layer hierarchy.

EM.Picasso's Layer Stack-up dialog showing the Embedded Sets tab.

Drawing Planar Objects on Horizontal Work Planes

As soon as you start drawing geometrical objects in the project workspace, the Physical Structure section of the navigation tree gets populated. The names of traces are added under their respective trace type category, and the names of objects appear under their respective trace group. At any time, one and only one trace is active in the project workspace. The name of the active trace in the navigation tree is always displayed in bold letters. An active trace is where all the new objects you draw belong to. By default, the last defined trace or embedded object set is active. You can immediately start drawing new objects on the active trace. You can also set any trace or object set group active at any time by right-clicking on its name on the navigation tree and selecting Activate from the contextual menu.

Info icon.png Click here to learn more about Moving Objects among Different Groups.

EM.Picasso's Navigation Tree populated with planar objects.

EM.Picasso has a special feature that makes construction of planar structures very convenient and straightforward. The horizontal Z-plane of the active trace or object set group is always set as the active work plane of the project workspace. That means all new objects are drawn at the Z-coordinate of the currently active trace. As you change the active trace group or add a new one, the active work plane changes accordingly.

Attention icon.png In EM.Picasso, you cannot modify the Z-coordinate of an object as it is set and controlled by its host trace.

EM.Picasso does not allow you to draw 3D or solid CAD objects. The solid object buttons in the Object Toolbar are disabled to prevent you from doing so. In order to create vias and embedded object, you simply have to draw their cross section geometry using planar surface CAD objects. EM.Picasso extrudes and extends these planar objects across their host layer automatically and displays them as 3D wireframe, prismatic objects. The automatic extrusion of embedded objects happens after mesh generation and before every planar MoM simulation. You can enforce this extrusion manually by right-clicking the Layer Stack-up item in the "Computational Domain" section of the navigation tree and selecting Update Planar Structure from the contextual menu.

Attention icon.png In EM.Picasso, you can only draw horizontal planar surface CAD objects.
A planar structure with a two-layer conductor-backed substrate, two PEC patches located at the tops of the lower and upper substrate layers, four PEC vias located inside the lower substrate layer between the lower patch and bottom ground and an embedded dielectric film located inside the top substrate layer sandwiched between the two patches.

EM.Picasso's Special Rules

  1. PEC ground planes at the top or bottom of a planar structure are regarded and modeled as PEC top or bottom half-spaces, respectively.
  2. A PEC ground plane placed in the middle of a substrate stack-up requires at least one slot object to provide electromagnetic coupling between its top and bottom sides. In this case, a slot trace is rather introduced at the given Z-plane, which also implies the presence of an infinite PEC ground.
  3. Metallic and slot traces cannot coexist on the same Z-plane. However, you can stack up multiple PEC and conductive sheet traces at the same Z-coordinate. Similarly, multiple slot traces can be placed at the same Z-coordinate.
  4. Metallic and slot traces are strictly defined at the interface planes between substrate layers. To define a suspended metallic trace inside a dielectric layer (as in the case of the center conductor of a stripline), you must split the dielectric layer into two thinner substrate layers and place your PEC trace at the interface between them.
  5. EM.Picasso's simulation engine is based on a 2.5-D MoM formulation. Only vertical volume currents and no circumferential components are allowed on embedded objects. The 2.5-D assumption holds very well in two cases: (a) when embedded objects are very thin with a very small cross section (with lateral dimensions less than 2-5% of the material wavelength) or (b) when embedded objects are very short and sandwiched between two closely spaced PEC traces or grounds from the top and bottom.

EM.Picasso's Excitation Sources

Your planar structure must be excited by some sort of signal source that induces electric surface currents on metal parts, magnetic surface currents on slot traces, and conduction or polarization volume currents on vertical vias and embedded objects. The excitation source you choose depends on the observables you seek in your project. EM.Picasso provides the following source types for exciting planar structures:

Icon Source Type Applications Restrictions
Gap src icon.png Strip Gap Circuit Source General-purpose point voltage source (or filament current source on slot traces) Associated with a PEC rectangle strip
Probe src icon.png Probe Gap Circuit Source General-purpose voltage source for modeling coaxial feeds Associated with an embedded PEC via set
Waveport src icon.png Scattering Wave Port Source Used for S-parameter computations Associated with an open-ended PEC rectangle strip, extends long from the open end
Hertz src icon.png Hertzian Short Dipole Source Almost omni-directional physical radiator None, stand-alone source
Plane wave icon.png Plane Wave Source Used for modeling scattering & computation of reflection/transmission characteristics of periodic surfaces None, stand-alone source
Huyg src icon.png Huygens Source Used for modeling equivalent sources imported from other EM.Cube modules Imported from a Huygens surface data file

Click on each category to learn more details about it in the Glossary of EM.Cube's Materials, Sources, Devices & Other Physical Object Types.

For antennas and planar circuits, where you typically define one or more ports, you usually use lumped sources. EM.Picasso provides three types of lumped sources: gap source, probe source and de-embedded source. A lumped source is indeed a gap discontinuity that is placed on the path of an electric or magnetic current flow, where a voltage or current source is connected to inject a signal. Gap sources are placed across metal or slot traces. A rectangle strip object on a PEC or conductive sheet trace acts like a strip transmission line that carries electric currents along its length (local X direction). The characteristic impedance of the line is a function of its width (local Y direction). A gap source placed on a narrow metal strip creates a uniform electric field across the gap and pumps electric current into the line. A rectangle strip object on a slot trace acts like a slot transmission line on an infinite PEC ground plane that carries a magnetic current along its length (local X direction). The characteristic impedance of the slot line is a function of its width (local Y direction). A gap source placed on a narrow slot represents an ideal current source. A slot gap acts like an ideal current filament, which creates electric fields across the slot, equivalent to a magnetic current flowing into the slot line. Probe sources are placed across vertical PEC vias. A de-embedded source is a special type of gap source that is placed near the open end of an elongated metal or slot trace to create a standing wave pattern, from which the scattering parameters can be calculated accurately.

Attention icon.png You can realize a coplanar waveguide (CPW) in EM.Picasso using two parallel slot lines with two aligned, collocated gap sources.

Info icon.png Click here to learn more about Using Source Arrays for Modeling Antenna Arrays.

A short dipole provides another way of exciting a planar structure in EM.Picasso. A short dipole source acts like an infinitesimally small ideal current source. You can also use an incident plane wave to excite your planar structure in EM.Picasso. In particular, you need a plane wave source to compute the radar cross section of a planar structure. The direction of incidence is defined by the θ and φ angles of the unit propagation vector in the spherical coordinate system. The default values of the incidence angles are θ = 180° and φ = 0° corresponding to a normally incident plane wave propagating along the -Z direction with a +X-polarized E-vector. Huygens sources are virtual equivalent sources that capture the radiated electric and magnetic fields from another structure that was previously analyzed in another EM.Cube computational module.

A multilayer planar structure containing a CPW line with a single coupled port and a lumped element on an overpassing metal strip.

Modeling Lumped Elements in EM.Picasso

Lumped elements are components, devices, or circuits whose overall dimensions are very small compared to the wavelength. As a result, they are considered to be dimensionless compared to the dimensions of a mesh cell. In fact, a lumped element is equivalent to an infinitesimally narrow gap that is placed in the path of current flow, across which the device's governing equations are enforced. Using Kirkhoff's laws, these device equations normally establish a relationship between the currents and voltages across the device or circuit. Crossing the bridge to Maxwell's domain, the device equations must now be cast into a from o boundary conditions that relate the electric and magnetic currents and fields. EM.Picasso allows you to define passive circuit elements: Resistors (R), Capacitors (C), Inductors (L), and series and parallel combinations of them.

Info icon.png Click here to learn more about Defining Lumped Elements.

Info icon.png Click here for a general discussion of Linear Passive Devices.

Attention icon.png The impedance of the lumped circuit is calculated at the operating frequency of the project using the specified R, L and C values. As you change the frequency, the value of the impedance that is passed to the Planar MoM engine will change.

Calculating Scattering Parameters Using Prony's Method

The calculation of the scattering (S) parameters is usually an important objective of modeling planar structures especially for planar circuits like filters, couplers, etc. As you saw earlier, you can use lumped sources like gaps and probes and even active lumped elements to calculate the circuit characteristics of planar structures. The admittance / impedance calculations based on the gap voltages and currents are accurate at RF and lower microwave frequencies or when the port transmission lines are narrow. In such cases, the electric or magnetic current distributions across the width of the port line are usually smooth, and quite uniform current or voltage profiles can easily be realized. At higher frequencies, however, a more robust method is needed for calculating the port parameters.

One can calculate the scattering parameters of a planar structure directly by analyzing the current distribution patterns on the port transmission lines. The discontinuity at the end of a port line typically gives rise to a standing wave pattern that can clearly be discerned in the line's current distribution. From the location of the current minima and maxima and their relative levels, one can determine the reflection coefficient at the discontinuity, i.e. the S11 parameter. A more robust technique is Prony’s method, which is used for exponential approximation of functions. A complex function f(x) can be expanded as a sum of complex exponentials in the following form:

[math] f(x) \approx \sum_{n=1}^N c_i e^{-j\gamma_i x} [/math]

where ci are complex coefficients and γi are, in general, complex exponents. From the physics of transmission lines, we know that lossless lines may support one or more propagating modes with pure real propagation constants (real γi exponents). Moreover, line discontinuities generate evanescent modes with pure imaginary propagation constants (imaginary γi exponents) that decay along the line as you move away from the location of such discontinuities.

In practical planar structures for which you want to calculate the scattering parameters, each port line normally supports one, and only one, dominant propagating mode. Multi-mode transmission lines are seldom used for practical RF and microwave applications. Nonetheless, each port line carries a superposition of incident and reflected dominant-mode propagating signals. An incident signal, by convention, is one that propagates along the line towards the discontinuity, where the phase reference plane is usually established. A reflected signal is one that propagates away from the port plane. Prony's method can be used to extract the incident and reflected propagating and evanescent exponential waves from the standing wave data. From a knowledge of the amplitudes (expansion coefficients) of the incident and reflected dominant propagating modes at all ports, the scattering matrix of the multi-port structure is then calculated. In Prony's method, the quality of the S parameter extraction results depends on the quality of the current samples and whether the port lines exhibit a dominant single-mode behavior. Clean current samples can be drawn in a region far from sources or discontinuities, typically a quarter wavelength away from the two ends of a feed line.

Minimum and maximum current locations of the standing wave pattern on a microstrip line feeding a patch antenna.

Defining Independent & Coupled Ports

Ports are used in a planar structure to order and index the sources for calculation of circuit parameters such as scattering (S), impedance (Z) and admittance (Y) parameters. In EM.Picasso, you can use one or more of the following types of sources to define ports:

  • Gap Sources
  • Probe Sources
  • Active Lumped Elements
  • De-Embedded Sources

Ports are defined in the Observables section of the navigation tree. You can define any number of ports equal to or less than the total number of sources in your project. If you have N sources in your planar structure, then N default ports are defined, with one port assigned to each source according to their order on the navigation tree. Note that your project can have mixed gap and probes sources as well as active lumped element sources on PEC and slot traces or vias. You can also couple ports together to define coupled transmission lines such as coupled strips (CPS) or coplanar waveguides (CPW).

Info icon.png Click here to learn more about the Port Definition Observable.

Info icon.png Click here to learn more about Modeling Coupled Ports.

EM.Picasso's Simulation Data & Observables

Depending on the source type and the types of observables defined in a project, a number of output data are generated at the end of a planar MoM simulation. Some of these data are 2D by nature and some are 3D. The output simulation data generated by EM.Picasso can be categorized into the following groups:

Icon Simulation Data Type Observable Type Applications Restrictions
Currdistr icon.png Current Distribution Maps Current Distribution Computing electric surface current distribution on metal traces and magnetic surface current distribution on slot traces None
Fieldsensor icon.png Near-Field Distribution Maps Near-Field Sensor Computing electric and magnetic field components on a specified plane in the frequency domain None
Farfield icon.png Far-Field Radiation Characteristics Far-Field Radiation Pattern Computing the radiation pattern and additional radiation characteristics such as directivity, axial ratio, side lobe levels, etc. None
Rcs icon.png Far-Field Scattering Characteristics Radar Cross Section (RCS) Computing the bistatic and monostatic RCS of a target Requires a plane wave source
Port icon.png Port Characteristics Port Definition Computing the S/Y/Z parameters and voltage standing wave ratio (VSWR) Requires one of these source types: lumped, distributed, microstrip, CPW, coaxial or waveguide port
Period icon.png Periodic Characteristics No observable required Computing the reflection and transmission coefficients of a periodic surface Requires a plane wave source and periodic boundary conditions
Huyg surf icon.png Equivalent electric and magnetic surface current data Huygens Surface Collecting tangential field data on a box to be used later as a Huygens source in other EM.Cube modules None

Click on each category to learn more details about it in the Glossary of EM.Cube's Simulation Observables & Graph Types.

If your planar structure is excited by gap sources or probe sources or de-embedded sources, and one or more ports have been defined, the planar MoM engine calculates the scattering, impedance and admittance (S/Z/Y) parameters of the designated ports. The scattering parameters are defined based on the port impedances specified in the project's Port Definition dialog. If more than one port has been defined in the project, the S/Z/Y matrices of the multiport network are calculated.

Electric and magnetic currents are the fundamental output data of a planar MoM simulation. After the numerical solution of the MoM linear system, they are found using the solution vector [I] and the definitions of the electric and magnetic vectorial basis functions:

[math] \mathbf{[X]}_{N\times 1} = \begin{bmatrix} I^{(J)} \\ \\ V^{(M)} \end{bmatrix} \quad \Rightarrow \quad \begin{cases} \mathbf{J(r)} = \sum_{n=1}^N I_n^{(J)} \mathbf{f_n^{(J)} (r)} \\ \\ \mathbf{M(r)} = \sum_{k=1}^K V_k^{(M)} \mathbf{f_k^{(M)} (r)} \end{cases} [/math]

Note that currents are complex vector quantities. Each electric or magnetic current has three X, Y and Z components, and each complex component has a magnitude and phase. You can visualize the surface electric currents on metal (PEC) and conductive sheet traces, surface magnetic currents on slot (PMC) traces and vertical volume currents on the PEV vias and embedded dielectric objects. 3D color-coded intensity plots of electric and magnetic current distributions are visualized in the project workspace, superimposed on the surface of physical objects. In order to view the current distributions, you must first define them as observables before running the planar MoM simulation. At the top of the Current Distribution dialog and in the section titled Active Trace / Set, you can select a trace or embedded object set where you want to observe the current distribution.

Attention icon.png You have to define a separate current distribution observable for each individual trace or embedded object set.
The current distribution map of a patch antenna.

EM.Picasso allows you to visualize the near fields at a specific field sensor plane. Note that unlike EM.Cube's other computational modules, near field calculations in EM.Picasso usually takes a significant amount of time. This is due to the fact that at the end of a planar MoM simulation, the fields are not available anywhere (as opposed to EM.Tempo), and their computation requires integration of complex dyadic Green's functions of a multilayer background structure as opposed to the free space Green's functions.

Attention icon.png Keep in mind that since EM.Picasso uses a planar MoM solver, the calculated field value at the source point is infinite. As a result, the field sensors must be placed at adequate distances (at least one or few wavelengths) away from the scatterers to produce acceptable results.
Near-zone electric field map above a microstrip-fed patch antenna.
Near-zone magnetic field map above a microstrip-fed patch antenna.

Even though EM.Picasso's MoM engine does not need a radiation box, you still have to define a "Far Field" observable for radiation pattern calculation. This is because far field calculations take time and you have to instruct EM.Cube to perform these calculations. Once a planar MoM simulation is finished, three far field items are added under the Far Field item in the Navigation Tree. These are the far field component in θ direction, the far field component in φ direction and the "Total" far field. The 2D radiation pattern graphs can be plotted from the Data Manager. A total of eight 2D radiation pattern graphs are available: 4 polar and 4 Cartesian graphs for the XY, YZ, ZX and user defined plane cuts.

Info icon.png Click here to learn more about the theory of Using Array Factors to Model Antenna Arrays .

3D polar radiation pattern plot of a microstrip-fed patch antenna.

When a planar structure is excited by a plane wave source, the calculated far field data indeed represent the scattered fields of that planar structure. EM.Picasso can also calculate the radar cross section (RCS) of a planar target. Note that in this case the RCS is defined for a finite-sized target in the presence of an infinite background structure. The scattered θ and φ components of the far-zone electric field are indeed what you see in the 3D far field visualization of radiation (scattering) patterns. Instead of radiation or scattering patterns, you can instruct EM.Picasso to plot 3D visualizations of σθ, σφ and the total RCS.

An example of the 3D monostatic radar cross section plot of a patch antenna.

Discretizing a Planar Structure in EM.Picasso

The method of moments (MoM) discretizes all the finite-sized objects of a planar structure (excluding the background structure) into a set of elementary cells. Both the quality and resolution of the generated mesh greatly affect the accuracy of the MoM numerical solution. The mesh density gives a measure of the number of cells per effective wavelength that are placed in various regions of your planar structure. The higher the mesh density, the more cells are created on the finite-sized geometrical objects. As a rule of thumb, a mesh density of about 20-30 cells per effective wavelength usually yields satisfactory results. But for structures with lots of fine geometrical details or for highly resonant structures, higher mesh densities may be required. The particular output data that you seek in a simulation also influence your choice of mesh resolution. For example, far field characteristics like radiation patterns are less sensitive to the mesh density than field distributions on structures with a highly irregular shapes and boundaries.

The Planar Mesh Settings dialog.

EM.Picasso provides two types of mesh for a planar structure: a pure triangular surface mesh and a hybrid triangular-rectangular surface mesh. In both case, EM.Picasso attempts to create a highly regular mesh, in which most of the cells have almost equal areas. For planar structures with regular, mostly rectangular shapes, the hybrid mesh generator usually leads to faster computation times.

Info icon.png Click here to learn more about Working with Mesh Generator.

Info icon.png Click here to learn more about EM.Picasso's Triangular Surface Mesh Generator.

Geometry of a multilayer slot-coupled patch array.
Hybrid planar mesh of the slot-coupled patch array.
Details of the hybrid planar mesh of the slot-coupled patch array around discontinuities.

The Hybrid Planar Mesh Generator

EM.Picasso's hybrid planar mesh generator tries to produce as many rectangular cells as possible especially in the case of objects with rectangular or linear boundaries. In connection or junction areas between adjacent objects or close to highly curved boundaries, triangular cells are used to fill the "irregular" regions in a conformal and consistent manner.

The mesh density gives a measure of the number of cells per effective wavelength that are placed in various regions of your planar structure. The effective wavelength is defined as [math]\lambda_{eff} = \tfrac{\lambda_0}{\sqrt{\varepsilon_{eff}}}[/math], where eeff is the effective permittivity. By default, EM.Picasso generates a hybrid mesh with a mesh density of 20 cells per effective wavelength. The effective permittivity is defined differently for different types of traces and embedded object sets. This is to make sure that enough cells are placed in areas that might feature higher field concentration.

  • For PEC and conductive sheet traces, the effective permittivity is defined as the larger of the permittivity of the two substrate layers just above and below the metallic trace.
  • For slot traces, the effective permittivity is defined as the mean (average) of the permittivity of the two substrate layers just above and below the metallic trace.
  • For embedded object sets, the effective permittivity is defined as the largest of the permittivities of all the substrate layers and embedded dielectric sets.
A comparison of triangular and planar hybrid meshes of a rectangular patch.
Mesh of two rectangular patches at two different substrate planes. The lower substrate layer has a higher permittivity.

General Rules of Planar Hybrid Mesh Generator

The integrity of the planar mesh and its continuity in the junction areas directly affects the quality and accuracy of the simulation results. EM.Picasso's hybrid planar mesh generator has some rules that are catered to 2.5-D MoM simulations:

  • If two connected rectangular objects have the same side dimensions along their common linear edge with perfect alignment, a rectangular junction mesh is produced.
  • If two connected rectangular objects have different side dimensions along their common linear edge or have edge offset, a set of triangular cells is generated along the edge of the object with the larger side.
  • Rectangle strip objects that host a gap source or a lumped element always have a rectangular mesh around the gap area.
  • If two objects reside on the same Z-plane, belong to the same trace group and have a common overlap area, they are first merged into a single object for the purpose of meshing using the "Boolean Union" operation.
  • Embedded objects have prismatic meshes along the Z-axis.
  • If an embedded object is located underneath or above a metallic trace object or connected from both top and bottom, it is meshed first and its mesh is then reflected on all of its attached horizontal trace objects.


PMOM36.png PMOM38.png PMOM37.png
Two overlapping planar objects and a comparison of their triangular and hybrid planar meshes.
PMOM33.png PMOM35.png PMOM34.png
Edge-connected rectangular planar objects and a comparison their triangular and hybrid planar meshes.
PMOM39.png PMOM40.png
Meshes of short and long vertical PEC vias connecting two horizontal metallic strips.

Refining the Planar Mesh Locally

It is very important to apply the right mesh density to capture all the geometrical details of your planar structure. This is especially true for "field discontinuity" regions such as junction areas between connected objects, where larger current concentrations are usually observed at sharp corners, or at the junction areas between metallic traces and PEC vias, as well as the areas around gap sources and lumped elements, which create voltage or current discontinuities.

The Planar Mesh Settings dialog gives a few options for customizing your planar mesh around geometrical and field discontinuities. The check box labeled "Refine Mesh at Junctions" increases the mesh resolution at the connection area between rectangular objects. The check box labeled "Refine Mesh at Gap Locations" might be particularly useful when gap sources or lumped elements are placed on a short transmission line connected from both ends. The check box labeled "Refine Mesh at Vias" increases the mesh resolution on the cross section of embedded object sets and at the connection regions of the metallic objects connected to them. EM.Picasso typically doubles the mesh resolution locally at the discontinuity areas when the respective boxes are checked. You should always visually inspect EM.Picasso's default generated mesh to see if the current mesh settings have produced an acceptable mesh.

Sometimes EM.Picasso's default mesh may contain very narrow triangular cells due to very small angles between two edges. In some rare cases, extremely small triangular cells may be generated, whose area is a small fraction of the average mesh cell. These cases typically happen at the junctions and other discontinuity regions or at the boundary of highly irregular geometries with extremely fine details. In such cases, increasing or decreasing the mesh density by one or few cells per effective wavelength often resolves that problem and eliminates those defective cells. Nonetheless, EM.Picasso's planar mesh generator offers an option to identify the defective triangular cells and either delete them or cure them. By curing we mean removing a narrow triangular cell and merging its two closely spaced nodes to fill the crack left behind. EM.Picasso by default deletes or cures all the triangular cells that have angles less than 10º. Sometimes removing defective cells may inadvertently cause worse problems in the mesh. You may choose to disable this feature and uncheck the box labeled "Remove Defective Triangular Cells" in the Planar Mesh Settings dialog. You can also change the value of the minimum allowable cell angle.

Attention icon.png Narrow, spiky triangular cells in a planar mesh are generally not desirable. You should get rid of the either by changing the mesh density or using the hybrid planar mesh generator's additional mesh refinement options.
Deleting or curing defective triangular cells: Case 1.
Deleting or curing defective triangular cells: Case 2.

Running Planar MoM Simulations in EM.Picasso

EM.Picasso's Simulation Modes

EM.Picasso offers five Planar MoM simulation modes:

Simulation Mode Usage Number of Engine Runs Frequency Restrictions
Single-Frequency Analysis Simulates the planar structure "As Is" Single run Runs at the center frequency fc None
Frequency Sweep Varies the operating frequency of the planar MoM solver Multiple runs Runs at a specified set of frequency samples or adds more frequency samples in an adaptive way None
Parametric Sweep Varies the value(s) of one or more project variables Multiple runs Runs at the center frequency fc None
Optimization Optimizes the value(s) of one or more project variables to achieve a design goal Multiple runs Runs at the center frequency fc None
HDMR Sweep Varies the value(s) of one or more project variables to generate a compact model Multiple runs Runs at the center frequency fc None

You can set the simulation mode from EM.Picasso's "Simulation Run Dialog". A single-frequency analysis is a single-run simulation. All the other simulation modes in the above list are considered multi-run simulations. If you run a simulation without having defined any observables, no data will be generated at the end of the simulation. In multi-run simulation modes, certain parameters are varied and a collection of simulation data files are generated. At the end of a sweep simulation, you can graph the simulation results in EM.Grid or you can animate the 3D simulation data from the navigation tree.

Running a Single-Frequency Planar MoM Analysis

A single-frequency analysis is the simplest type of EM.Picasso simulation and involves the following steps:

  • Set the units of your project and the frequency of operation. Note that the default project unit is millimeter.
  • Define you background structure and its layer properties and trace types.
  • Construct your planar structure using CubeCAD's drawing tools to create all the finite-sized metal and slot trace objects and possibly embedded metal or dielectric objects that are interspersed among the substrate layers.
  • Define an excitation source and observables for your project.
  • Examine the planar mesh, verify its integrity and change the mesh density if necessary.
  • Run the Planar MoM simulation engine.
  • Visualize the output simulation data.

To run a planar MoM analysis of your project structure, open the Run Simulation Dialog by clicking the Run Run icon.png button on the Simulate Toolbar or select Menu > Simulate > Run or use the keyboard shortcut Ctrl+R. The Single-Frequency Analysis option of the Simulation Mode dropdown list is selected by default. Once you click the Run button, the simulation starts. A new window called the "Output Window" opens up that reports the different stages of simulation and the percentage of the tasks completed at any time. After the simulation is successfully completed, a message pops up and reports the end of simulation. In certain cases like calculating scattering parameters of a circuit or reflection / transmission characteristics of a periodic surface, some results are also reported in the output window.

EM.Picasso's Simulation Run dialog.

Setting Numerical Parameters

A planar MoM simulation involves a number of numerical parameters that take preset default values unless you change them. You can access these parameters and change their values by clicking the Settings button next to the Select Engine drop-down list in EM.Picasso's Simulation Run dialog. In most cases, you do not need to open this dialog and you can leave all the default numerical parameter values intact. However, it is useful to familiarize yourself with these parameters, as they may affect the accuracy of your numerical results.

The Planar MoM Engine Settings Dialog is organized in a number of sections. Here we describe some of the numerical parameters. The "Matrix Fill" section of the dialog deals with the operations involving the dyadic Green's functions. You can set a value for the Convergence Rate for Integration, which is 1E-5 by default. This is used for the convergence test of all the infinite integrals in the calculation of the Hankel transform of spectral-domain dyadic Green's functions. When the substrate is lossy, the surface wave poles are captured in the complex integration plane using contour deformation. You can change the maximum number of iterations involved in this deformed contour integration, whose default value is 20. When the substrate is very thin with respect to the wavelength, the dyadic Green's functions exhibit numerical instability. Additional singularity extraction measures are taken to avoid numerical instability but at the expense of increased computation time. By default, a thin substrate layer is defined to a have a thickness less than 0.01λeff, where λeff is the effective wavelength. You can modify the definition of "Thin Substrate" by entering a value for Thin Substrate Threshold different than the default 0.01. The parameter Max Coupling Range determines the distance threshold in wavelength between the observation and source points after which the Green's interactions are neglected. This distance by default is set to 1,000 wavelengths. For electrically small structures, the phase variation across the structure may be negligible. In such cases, a fast quasi-static analysis can be carried out. You can set this threshold in wavelengths in the box labeled Max Dimensions for Quasi-Static Analysis.

In the "Spectral Domain Integration" section of the dialog, you can set a value to Max Spectral Radius in k0, which has a default value of 30. This means that the infinite spectral-domain integrals in the spectral variable kρ are pre-calculated and tabulated up to a limit of 30k0, where k0 is the free space propagation constant. These integrals may converge much faster based on the specified Convergence Rate for Integration described earlier. However, in certain cases involving highly oscillatory integrands, much larger integration limits like 100k0 might be needed to warrant adequate convergence. For spectral-domain integration along the real kρ axis, the interval [0, Nk0] is subdivided into a large number of sub-intervals, within each an 8-point Gauss-Legendre quadrature is applied. The next parameter, No. Radial Integration Divisions per k0, determines how small these intervals should be. By default, 2 divisions are used for the interval [0, k0]. In other words, the length of each integration sub-interval is k0/2. You can increase the resolution of integration by increasing this value above 2. Finally, instead of 2D Cartesian integration in the spectral domain, a polar integration is performed. You can set the No. of Angular Integration Points, which has a default value of 100.

EM.Picasso provides a large selection of linear system solvers including both direct and iterative methods. EM.Picasso, by default, provides a "Automatic" solver option that picks the best method based on the settings and size of the numerical problem. For linear systems with a size less than N = 3,000, the LU solver is used. For larger systems, BiCG is used when dealing with symmetric matrices, and GMRES is used for asymmetric matrices. You can instruct EM.Cube to write the MoM matrix and excitation and solution vectors into output data files for your examination. To do so, check the box labeled "Output MoM Matrix and Vectors" in the Matrix Fill section of the Planar MoM Engine Settings dialog. These are written into three files called mom.dat1, exc.dat1 and soln.dat1, respectively.

EM.Picasso's Planar MoM Engine Settings dialog.

Modeling Periodic Planar Structures in EM.Picasso

EM.Picasso allows you to simulate doubly periodic planar structures with periodicities along the X and Y directions. Once you designate your planar structure as periodic, EM.Picasso's Planar MoM simulation engine uses a spectral domain solver to analyze it. In this case, the dyadic Green's functions of periodic planar structure take the form of doubly infinite summations rather than integrals.

Info icon.png Click here to learn more about the theory of Periodic Green's functions.

Attention icon.png EM.Picasso can handle both regular and skewed periodic lattices.


Defining a Periodic Structure in EM.Picasso

An infinite periodic structure in EM.Picasso is represented by a "Periodic Unit Cell". To define a periodic structure, you must open EM.Picasso's Periodicity Settings Dialog by right clicking the Periodicity item in the Computational Domain section of the navigation tree and selecting Periodicity Settings... from the contextual menu or by selecting Menu > Simulate > 'Computational Domain > Periodicity Settings... from the menu bar. In the Periodicity Settings Dialog, check the box labeled Periodic Structure. This will enable the section titled"Lattice Properties". You can define the periods along the X and Y axes using the boxes labeled Spacing. In a periodic structure, the virtual domain is replaced by a default blue periodic domain that is always centered around the origin of coordinates. Keep in mind that the periodic unit cell must always be centered at the origin of coordinates. The relative position of the structure within this centered unit cell will change the phase of the results.

EM.Picasso's Periodicity Settings dialog.

In many cases, your planar structure's traces or embedded objects are entirely enclosed inside the periodic unit cell and do not touch the boundary of the unit cell. EM.Picasso allows you to define periodic structures whose unit cells are interconnected. The interconnectivity applies only to PEC, PMC and conductive sheet traces, and embedded object sets are excluded. Your objects cannot cross the periodic domain. In other words, the neighboring unit cells cannot overlap one another. However, you can arrange objects with linear edges such that one or more flat edges line up with the domain's bounding box. In such cases, EM.Picasso's planar MoM mesh generator will take into account the continuity of the currents across the adjacent connected unit cells and will create the connection basis functions at the right and top boundaries of the unit cell. It is clear that due to periodicity, the basis functions do not need to be extended at the left or bottom boundaries of the unit cell. As an example, consider a periodic metallic screen as shown in the figure on the right. The unit cell of this structure can be defined as a rectangular aperture in a PEC ground plane (marked as Unit Cell 1). In this case, the rectangle object is defined as a slot trace. Alternatively, you can define a unit cell in the form of a microstrip cross on a metal trace. In the latter case, however, the microstrip cross should extend across the unit cell and connect to the crosses in the neighboring cells in order to provide current continuity.

Modeling a periodic screen using two different types of unit cell.
The PEC cross unit cell.
Planar mesh of the PEC cross unit cell. Note the cell extensions at the unit cell's boundaries.

Exciting Periodic Structures as Radiators in EM.Picasso

When a periodic planar structure is excited using a gap or probe source, it acts like an infinite periodic phased array. All the periodic replicas of the unit cell structure are excited. You can even impose a phase progression across the infinite array to steer its beam. You can do this from the property dialog of the gap or probe source. At the bottom of the Planar Gap Circuit Source Dialog or Gap Source Dialog, there is a button titled Periodic Scan.... You can enter desired values for Theta and Phi beam scan angles in degrees. To visualize the radiation patterns of a beam-steered antenna array, you have to define a finite-sized array factor in the Radiation Pattern dialog. You do this in the Impose Array Factor section of this dialog. The values of Element Spacing along the X and Y directions must be set equal to the value of Periodic Lattice Spacing along those directions.

Setting periodic scan angles in EM.Picasso's Gap Source dialog.
Setting the beam scan angles in Periodic Scan Angles dialog.
Setting the array factor in EM.Picasso's Radiation Pattern dialog.
Radiation pattern of an 8×8 finite-sized periodic printed dipole array with 0° phi and theta scan angles.
Radiation pattern of a beam-steered 8×8 finite-sized periodic printed dipole array with 45° phi and theta scan angles.

Exciting Periodic Structures Using Plane Waves in EM.Picasso

When a periodic planar structure is excited using a plane wave source, it acts as a periodic surface that reflects or transmits the incident wave. EM.Picasso calculates the reflection and transmission coefficients of periodic planar structures. If you run a single-frequency plane wave simulation, the reflection and transmission coefficients are reported in the Output Window at the end of the simulation. Note that these periodic characteristics depend on the polarization of the incident plane wave. You set the polarization (TMz or TEz) in the Plane Wave Dialog when defining your excitation source. In this dialog you also set the values of the incident Theta and Phi angles. At the end of the planar MoM simulation of a periodic structure with plane wave excitation, the reflection and transmission coefficients of the structure are calculated and saved into two complex data files called "reflection.CPX" and "transmission.CPX".

Attention icon.png In the absence of any finite traces or embedded objects in the project workspace, EM.Picasso computes the reflection and transmission coefficients of the layered background structure of your project.
A periodic planar layered structure with slot traces excited by a normally incident plane wave source.

Running a Periodic MoM Analysis

You run a periodic MoM analysis just like an aperiodic MoM simulation from EM.Picasso's Run Dialog. Here, too, you can run a single-frequency analysis or a uniform or adaptive frequency sweep, or a parametric sweep, etc. Similar to the aperiodic structures, you can define several observables for your project. If you open the Planar MoM Engine Settings dialog, you will see a section titled "Infinite Periodic Simulation". In this section, you can set the number of Floquet modes that will be computed in the periodic Green's function summations. By default, the numbers of Floquet modes along the X and Y directions are both equal to 25, meaning that a total of 2500 Floquet terms will be computed for each periodic MoM simulation.

Changing the number of Floquet modes from the Planar MoM Engine Settings dialog.

You learned earlier how to use EM.Cube's powerful, adaptive frequency sweep utility to study the frequency response of a planar structure. Adaptive frequency sweep uses rational function interpolation to generate smooth curves of the scattering parameters with a relatively small number of full-wave simulation runs in a progressive manner. Therefore, you need a port definition in your planar structure to be able to run an adaptive frequency sweep. This is clear in the case of an infinite periodic phased array, where your periodic unit cell structure must be excited using either a gap source or a probe source. You run an adaptive frequency sweep of an infinite periodic phased array in exactly the same way to do for regular, aperiodic, planar structures.

EM.Cube's Planar Modules also allows you to run an adaptive frequency sweep of periodic surfaces excited by a plane wave source. In this case, the planar MoM engine calculates the reflection and transmission coefficients of the periodic surface. Note that you can conceptually consider a periodic surface as a two-port network, where Port 1 is the top half-space and Port 2 is the bottom half-space. In that case, the reflection coefficient R is equivalent to S11 parameter, while the transmission coefficient T is equivalent to S21 parameter. This is, of course, the case when the periodic surface is illuminated by the plane wave source from the top half-space, corresponding to 90°< θ = 180°. You can also illuminate the periodic surface by the plane wave source from the bottom half-space, corresponding to 0° = θ < 90°. In this case, the reflection coefficient R and transmission coefficient T are equivalent to S22 and S12 parameters, respectively. Having these interpretations in mind, EM.Cube enables the "Adaptive Frequency Sweep" option of the Frequency Settings Dialog when your planar structure has a periodic domain together with a plane wave source.




Top icon.png Back to the Top of the Page

Tutorial icon.png EM.Picasso Tutorial Gateway

Back icon.png Back to EM.Cube Main Page